ICD-10 Logo
ICDxICD-10 Medical Coding
ICD-10 Logo
ICDxICD-10 Medical Coding
ICD 10 CodesDiagnoses
ICD 10 CodesDiagnoses
ICD-10 Logo
ICDxICD-10 Medical Coding

Comprehensive ICD-10-CM code reference with AI-powered search capabilities.

© 2025 ICD Code Compass. All rights reserved.

Browse

  • All Chapters
  • All Categories
  • Diagnoses

Tools

  • AI Code Search
ICD-10-CM codes are maintained by the CDC and CMS. This tool is for reference purposes only.
v1.0.0
ICD-10 Guide
ICD-10 CodesG97.0

G97.0

Billable

Cerebrospinal fluid leak from spinal puncture

BILLABLE STATUSYes
IMPLEMENTATION DATEOctober 1, 2015
LAST UPDATED09/05/2025

Code Description

ICD-10 G97.0 is a billable code used to indicate a diagnosis of cerebrospinal fluid leak from spinal puncture.

Key Diagnostic Point:

Cerebrospinal fluid (CSF) leak from spinal puncture occurs when there is an unintended escape of CSF from the spinal canal following a lumbar puncture or spinal tap. This condition can lead to a variety of symptoms, primarily characterized by postural headaches, which are exacerbated by standing or sitting and relieved by lying down. Other symptoms may include neck stiffness, nausea, vomiting, and in some cases, neurological deficits due to decreased CSF pressure. The leak can result in complications such as hydrocephalus, where the accumulation of CSF leads to increased intracranial pressure, and autonomic dysfunction, which may manifest as changes in heart rate and blood pressure. Diagnosis typically involves clinical evaluation and may be supported by imaging studies or a repeat lumbar puncture to confirm the leak. Management may include conservative measures such as hydration and caffeine intake, or more invasive procedures like an epidural blood patch to seal the leak. Understanding the implications of CSF leaks is crucial for healthcare providers, as they can lead to significant morbidity if not properly addressed.

Code Complexity Analysis

Complexity Rating: Medium

Medium Complexity

Complexity Factors

  • Differentiating between intentional and unintentional CSF leaks
  • Understanding the clinical implications of CSF leaks
  • Documenting associated symptoms and complications accurately
  • Navigating the coding guidelines for related conditions

Audit Risk Factors

  • Inadequate documentation of the procedure leading to the leak
  • Failure to note associated symptoms or complications
  • Misclassification of the type of CSF leak
  • Inconsistent coding of related neurological conditions

Specialty Focus

Medical Specialties

Neurology

Documentation Requirements

Detailed documentation of symptoms, diagnostic tests, and treatment plans is essential.

Common Clinical Scenarios

Patients presenting with post-lumbar puncture headaches or neurological deficits.

Billing Considerations

Neurologists should ensure that all associated symptoms and potential complications are documented to support the diagnosis.

Anesthesiology

Documentation Requirements

Thorough records of the procedure, including technique and patient response.

Common Clinical Scenarios

Patients undergoing spinal anesthesia or lumbar puncture for diagnostic purposes.

Billing Considerations

Anesthesiologists must document the indication for the procedure and any immediate complications.

Coding Guidelines

Inclusion Criteria

Use G97.0 When
  • According to the official coding guidelines, G97
  • 0 should be used when the cerebrospinal fluid leak is directly attributable to a spinal puncture
  • Coders must ensure that the documentation supports the diagnosis and that any related conditions are also coded appropriately

Exclusion Criteria

Do NOT use G97.0 When
No specific exclusions found.

Related ICD-10 Codes

Related CPT Codes

62270CPT Code

Lumbar puncture, diagnostic

Clinical Scenario

Used when performing a lumbar puncture that may lead to a CSF leak.

Documentation Requirements

Document the indication for the procedure, technique used, and any complications.

Specialty Considerations

Anesthesiologists and neurologists should ensure that the procedure is well-documented to support coding.

ICD-10 Impact

Diagnostic & Documentation Impact

Enhanced Specificity

ICD-10 Improvements

The transition to ICD-10 has allowed for more specific coding of conditions like CSF leaks, improving the accuracy of data collection and reimbursement processes. G97.0 provides a clear distinction from other types of CSF leaks, facilitating better patient management and research.

ICD-9 vs ICD-10

The transition to ICD-10 has allowed for more specific coding of conditions like CSF leaks, improving the accuracy of data collection and reimbursement processes. G97.0 provides a clear distinction from other types of CSF leaks, facilitating better patient management and research.

Reimbursement & Billing Impact

reimbursement processes. G97.0 provides a clear distinction from other types of CSF leaks, facilitating better patient management and research.

Resources

Clinical References

  • •
    ICD-10-CM Official Guidelines for Coding and Reporting

Coding & Billing References

  • •
    ICD-10-CM Official Guidelines for Coding and Reporting

Frequently Asked Questions

What are the common symptoms of a CSF leak?

Common symptoms include severe headaches that worsen when sitting or standing, neck stiffness, nausea, and in some cases, neurological deficits.

How is a CSF leak diagnosed?

Diagnosis typically involves a clinical evaluation, imaging studies, and sometimes a repeat lumbar puncture to confirm the leak.

What treatment options are available for a CSF leak?

Treatment may include conservative measures such as hydration and caffeine, or more invasive procedures like an epidural blood patch.